Type of connectors 2RT-A
 |
Application
They are used in radio electronic and radio engineering equipment as connectors of the general type.
Standarts
OST V 11 0121-91
GE0.364.118 Specification
bRO.364.032 Specification
Design description
- screw mating
- climatic version UHL
- contacts plating: silver, nickel
- mounting method: soldering
|
Characteristics
Mechanical
|
| vibration: |
frequency range, Hz - 1…1000
acceleration, m/s2 - 100 (10g) |
single impacts:
|
acceleration, m/s2 - 10000 (1000g) |
| multiple impacts: |
acceleration, m/s2 - 1500 (150g) |
linear loads:
|
acceleration, m/s2 - 2000 (200g) |
| |
|
Reliability requirements
|
|
| minimum operating time, h |
1000 |
with mate-unmate operations
|
500 |
minimum storage life, years
|
20 |
| |
|
Electric
|
| maximum direct current operating voltage, not more than |
700 V |
operating current across the contact,
not more than |
ref. contacts location diagrams |
| resistance of electric contact, not more than, mOhm |
plating: silver
1,5 - 2,5
2,5 - 1,0
3,5 - 0,75
5,5 - 0,3
9,0 - 0,15 |
| |
plating: nickel
1,5 - 5,0
2,5 - 2,5
3,5 - 1,5
5,5 - 0,75
9,0 - 0,6 |
| insulation resistance in normal climatic conditions, not less than |
1000 MOhm |
| |
|
Climatic
|
| ambient air temperature |
from minus 60 - to plus 100°Ñ |
| change of temperature |
from minus 60 °Ñ - to plus 180°Ñ
(taking in the account the temperature of contacts overheat) |
atmospheric pressure decrease, operating
Pa (mm.Hg)
|
1,3õ10-4 (1õ10-6) |
Designation
| |
2RT |
20 |
PK |
2 |
EA |
SH |
6 |
-À |
N |
| Type |
|
|
|
|
|
|
|
|
| Dimension type |
Design version:
Fixed connector
P - without pipe
PK - with straight pipe
SK - with angled pipe
Cable connector
P - with straight pipe
U - with angled pipe |
| Number of contacts |
Type of nut for the pipe
EA - for shielded cable (ref. note 2)
N - for non-shielded cable |
Type of contacts:
Fixed connector
SH - plug (male connector)
G - socket (female connector)
Cable connector:
SH - socket (female connector)
G - plug (male connector)(ref. note 3) |
| Combination of contacts (ref. contacts location diagrams) |
| Additional designation - regarding insert material |
Additional element for connectors, manufactured as specified in bRO.364.032 Specificati
N - nickel plating |
Notes:
1.The type of connector additionally includes designation of material "A"
2.There is no nut in the fixed connector without pipe. Designation "EA" - conventional.
3.Type of the contacts in the cable connector is conventionally designated depending on the type of contacts in fixed connector, with which it is mated.
Designation while placing the order:
Plug 2RT48P2EASH9À GE0.364.118 Specification
Socket 2RT48U2NSH9À GE0.364.118 Specification
|
|