Mechanical
|
| vibration: |
frequency range, Hz - 1…2000
acceleration, m/s2- 300 (30g)
|
| single impacts: |
acceleration, m/s2 - 1500 (150g) |
| multiple impacts: |
acceleration, m/s2 - 350 (35g) |
| linear loads: |
acceleration, m/s2 - 500 (50g) |
| |
|
Reliability requirements
|
| minimum operating time, h |
10000 |
| with mate-unmate operations |
1000 |
| minimum storage life, years |
15 |
| |
|
Electric
|
maximum operating voltage, not more thanmaximum operating direct current voltage or amplitude voltage value of alternative current
|
ref. table 2 |
operating current across the contact
|
ref. table 1 |
resistance of electric contact, not more than
|
for low frequency contacts- 2,5 mOhm
for radio frequency contacts-10mOhm |
insulation resistance in normal climatic conditions, not less than
|
for low frequency - 5000 MOhm
for radio frequency - 1000 ÌOhm |
| |
|
Climatic
|
| ambient air temperature, °Ñ |
from minus 60°C - to plus 100 °C |
| change of temperature, °Ñ |
from minus 60 °C- to plus 130°C
(taking in the account the temperature of contacts overheat) |
atmospheric pressure decrease, operating
Pa (mm.Hg)
|
0,13 (1õ10-3) |